DataRateKit

How long does copying 5 GB take over SATA SSD to internal HDD?

Local transfer
Planning estimate (85%)

Copying 5 GB over SATA SSD to internal HDD takes 28 seconds at the raw bottleneck limit (180 MB/s / 1,440 Mbps). With an 85% planning assumption (153 MB/s / 1,224 Mbps), the planning estimate is 33 seconds.

Planning estimate (85%)33 seconds
Theoretical result (100%)28 seconds

85% is a planning assumption accounting for filesystem, protocol, and cache overhead—not a guaranteed device speed.

File size5 GB
Transfer profileSATA SSD to internal HDD
Pipeline bottleneckDestination drive write limit (180 MB/s / 1,440 Mbps)
Theoretical result (100%)28 seconds
Planning estimate (85%)33 seconds
Planning effective rate153 MB/s / 1,224 Mbps
Total bytes (SI decimal)5,000,000,000 bytes
Total bits40,000,000,000 bits

Local Storage Transfer Comparison

Transfer profileTheoreticalPlanningPlanning effective rate
USB 2.0 (480 Mbps nominal)2 minutes and 5 seconds2 minutes and 27 seconds34 MB/s / 272 Mbps
SD UHS-I card to SSD56 seconds1 minute and 5 seconds76.5 MB/s / 612 Mbps
External USB 3.0 HDD to NVMe42 seconds49 seconds102 MB/s / 816 Mbps
SATA SSD to internal HDDCurrent selection28 seconds33 seconds153 MB/s / 1,224 Mbps
Internal HDD to SATA SSD25 seconds29 seconds170 MB/s / 1,360 Mbps
SD UHS-II card to NVMe20 seconds24 seconds213 MB/s / 1,700 Mbps
SATA SSD to SATA SSD10 seconds12 seconds425 MB/s / 3,400 Mbps
USB 3.0 / 3.2 Gen 1 (5 Gbps)8 seconds9.4 seconds531 MB/s / 4,250 Mbps

Efficiency Sensitivity & Neighboring Storage Profiles

Transfer profileTheoreticalPlanningPlanning effective rate
Reference calculation56 seconds1 minute and 5 seconds76.5 MB/s / 612 Mbps
Reference calculation42 seconds49 seconds102 MB/s / 816 Mbps
Reference calculation25 seconds29 seconds170 MB/s / 1,360 Mbps
Reference calculation20 seconds24 seconds213 MB/s / 1,700 Mbps
100% sustained efficiency assumption
Calculated scenario
28 seconds28 seconds180 MB/s / 1,440 Mbps
85% sustained efficiency assumption
Calculated scenario
28 seconds33 seconds153 MB/s / 1,224 Mbps
70% sustained efficiency assumption
Calculated scenario
28 seconds40 seconds126 MB/s / 1,008 Mbps

Local Drive Copies & Removable Media Offloads

When This Calculation Applies: This estimate is useful when comparing bus and storage bottlenecks before moving files between internal SSDs, external drives, or memory cards.

How This Is Calculated

Calculations use SI decimal file sizes (1 MB = 1,000,000 bytes; 1 GB = 1,000³ bytes). The transfer pipeline is bounded by the slowest stage among source, interface, and destination (Destination drive write limit at 180 MB/s / 1,440 Mbps). Theoretical time divides total megabytes by that bottleneck limit, while the planning estimate applies a 85% planning assumption.

Try Your Own Values

Calculation Mode
Transfer Path Pipeline3-Stage End-to-EndThroughput is capped by the slowest stage
1. Source ReadInternal / local drive reading speed
2. Interface / BusLAN, USB, Thunderbolt or bus rate
3. Destination WriteTarget drive / NAS write speed
Bottleneck
Planning efficiency applies an adjustable allowance for protocol, filesystem, device, and thermal overhead. It is an editable assumption, not a guaranteed rate.
Estimated Transfer Duration33 secondsPrimary Bottleneck: Destination Write (180 MB/s raw limit)
Effective Throughput153 MB/s (1,224 Mbps)
Data Per Hour550.8 GB/hr
Pure Data Time33 seconds
Source Headroom: 178% ( +320 MB/s)
Interface Headroom: 317% ( +570 MB/s)
Destination Headroom: 0% ( +0 MB/s)
Transfer throughput is capped by Destination Write at 180 MB/s raw. At 85% planning efficiency, sustained throughput is 153 MB/s.

85% is a planning assumption accounting for filesystem, protocol, and cache overhead—not a guaranteed device speed.

Open interactive calculator to adjust size, speed, or efficiency

Calculation Questions

Why is the 85% local planning estimate for 5 GB over SATA SSD to internal HDD slower than nominal speed?

The SATA SSD to internal HDD profile is limited by its bottleneck (Destination drive write limit) at 180 MB/s / 1,440 Mbps. Applying the 85% planning assumption (153 MB/s / 1,224 Mbps) accounts for protocol framing and cache overhead, resulting in 33 seconds instead of 28 seconds.

Related Calculations