DataRateKit

How long does copying 75 GB take over USB 3.2 Gen 2x2 (20 Gbps)?

Local transfer
Planning estimate (85%)

Copying 75 GB over USB 3.2 Gen 2x2 (20 Gbps) takes 30 seconds at the raw bottleneck limit (2,500 MB/s / 20,000 Mbps). With an 85% planning assumption (2,125 MB/s / 17,000 Mbps), the planning estimate is 35 seconds.

Planning estimate (85%)35 seconds
Theoretical result (100%)30 seconds

85% is a planning assumption accounting for filesystem, protocol, and cache overhead—not a guaranteed device speed.

File size75 GB
Transfer profileUSB 3.2 Gen 2x2 (20 Gbps)
Pipeline bottleneckInterface / link limit (2,500 MB/s / 20,000 Mbps)
Theoretical result (100%)30 seconds
Planning estimate (85%)35 seconds
Planning effective rate2,125 MB/s / 17,000 Mbps
Total bytes (SI decimal)75,000,000,000 bytes
Total bits600,000,000,000 bits

Local Storage Transfer Comparison

Transfer profileTheoreticalPlanningPlanning effective rate
SATA SSD to SATA SSD2 minutes and 30 seconds2 minutes and 56 seconds425 MB/s / 3,400 Mbps
USB 3.0 / 3.2 Gen 1 (5 Gbps)2 minutes2 minutes and 21 seconds531 MB/s / 4,250 Mbps
USB 3.2 Gen 2 (10 Gbps)1 minute1 minute and 11 seconds1,063 MB/s / 8,500 Mbps
CFexpress Type B card to NVMe44 seconds52 seconds1,445 MB/s / 11,560 Mbps
USB 3.2 Gen 2x2 (20 Gbps)Current selection30 seconds35 seconds2,125 MB/s / 17,000 Mbps
NVMe PCIe 3.0 to NVMe PCIe 3.021 seconds25 seconds2,975 MB/s / 23,800 Mbps
USB4 / Thunderbolt 4 external SSD20 seconds23 seconds3,230 MB/s / 25,840 Mbps
NVMe PCIe 4.0 to NVMe PCIe 4.015 seconds18 seconds4,250 MB/s / 34,000 Mbps

Efficiency Sensitivity & Neighboring Storage Profiles

Transfer profileTheoreticalPlanningPlanning effective rate
Reference calculation1 minute1 minute and 11 seconds1,063 MB/s / 8,500 Mbps
Reference calculation44 seconds52 seconds1,445 MB/s / 11,560 Mbps
Reference calculation21 seconds25 seconds2,975 MB/s / 23,800 Mbps
Reference calculation20 seconds23 seconds3,230 MB/s / 25,840 Mbps
100% sustained efficiency assumption
Calculated scenario
30 seconds30 seconds2,500 MB/s / 20,000 Mbps
85% sustained efficiency assumption
Calculated scenario
30 seconds35 seconds2,125 MB/s / 17,000 Mbps
70% sustained efficiency assumption
Calculated scenario
30 seconds43 seconds1,750 MB/s / 14,000 Mbps

Local Drive Copies & Removable Media Offloads

When This Calculation Applies: This estimate is useful when comparing bus and storage bottlenecks before moving files between internal SSDs, external drives, or memory cards.

How This Is Calculated

Calculations use SI decimal file sizes (1 MB = 1,000,000 bytes; 1 GB = 1,000³ bytes). The transfer pipeline is bounded by the slowest stage among source, interface, and destination (Interface / link limit at 2,500 MB/s / 20,000 Mbps). Theoretical time divides total megabytes by that bottleneck limit, while the planning estimate applies a 85% planning assumption.

Try Your Own Values

Calculation Mode
Transfer Path Pipeline3-Stage End-to-EndThroughput is capped by the slowest stage
1. Source ReadInternal / local drive reading speed
2. Interface / BusLAN, USB, Thunderbolt or bus rate
Bottleneck
3. Destination WriteTarget drive / NAS write speed
Planning efficiency applies an adjustable allowance for protocol, filesystem, device, and thermal overhead. It is an editable assumption, not a guaranteed rate.
Estimated Transfer Duration35 secondsPrimary Bottleneck: Interface / Network (2,500 MB/s raw limit)
Effective Throughput2,125 MB/s (17,000 Mbps)
Data Per Hour7,650 GB/hr
Pure Data Time35 seconds
Source Headroom: 40% ( +1,000 MB/s)
Interface Headroom: 0% ( +0 MB/s)
Destination Headroom: 20% ( +500 MB/s)
Transfer throughput is capped by Interface / Network at 2,500 MB/s raw. At 85% planning efficiency, sustained throughput is 2,125 MB/s.

85% is a planning assumption accounting for filesystem, protocol, and cache overhead—not a guaranteed device speed.

Open interactive calculator to adjust size, speed, or efficiency

Related Calculations